Biomedical, Engineering and physical science

High Sensitivity Detection of Contaminates in Heparin

The technology

Market need

Heparin is known for its uses as an anticoagulant. Since heparin is a naturally occurring polysaccharide, it needs to be purified for human use. Heparin lots could be contaminated by a related molecule called oversulfated chondroitin sulfate (OSCS). OSCS is unsafe for human use and results in a variety of reactions including severe anaphylaxis, drop in blood pressure, and possible death. The FDA requires all heparin lots be tested for purity before they are manufactured into medications. Several methods exist for detection of OSCS; however, they are not always very accurate or sensitive. Some detection methods are capable of sensing very small levels of contamination but they cannot detect larger levels of the impurity, requiring multiple methods be used which is costly and fraught with a high margin of error.

Technology summary

This method is able to detect an amount as low as 10-9 % w/w OSCS in heparin, about 6 orders of magnitude more sensitive than current tests. This test can be performed rapidly with some levels of contamination apparent in a matter of minutes and full sensitivity after a half hour. The test consists of a gold nanoparticle sensor covered with heparin and a dye. The contaminant is an inhibitor of the enzyme heparitinase. When the heparin lot in question is pure, the enzyme will cause the nanosensor to fluoresce. When the lot is contaminated, the enzyme will not disrupt the sensor’s heparin coating and will not activate the dye. The figure shows the relative radiant efficiencies to the amount of contamination.

Chart showing increasing activity of enzyme, relative radiant efficiency vs increasing amount of contamination [View Image]

Technology status

In vivo imaging system validation of the sensitivity of the fluorescent detection to 10-9 % w/w OSCS impurity.

Download PDF

Benefits:

  • Prevents adverse patient events and product recalls
  • Sensitive for detecting OSCS contamination as low as 100 parts per billion
  • Rapid results-test completed in less than an hour
  • Requires only a small amount of the lot for testing

Applications:

  • Heparin lot quality test
  • Quality control/ assurance of purity
  • Manufacturing safety validation
  • Calibrate the activity of commercial heparitinase enzyme
  • Provides assurance to healthcare providers and consumers
  • FDA compliance testing

Additional information

Investigators:

Umesh Desai, Ph.D.

Patent status:

Patent Pending: U.S. and Foreign rights are available.

License status:

This technology is available for licensing to industry for further development and commercialization.

Category:

Biomedical, Engineering and physical science

VCU Tech #:

13-070